1. Prepare the surface of installation area by removing stones, roots, etc., filling any voids in order to obtain a smooth and compact laying surface.

2. Excavate the top and bottom anchor trenches (if required by the engineer). Place TENAX MULTIMAT in the upper trench and fix with "U" (F = 8 mm) shaped pins (length of pins is normally 150-300 mm depending on consistency of the sub-grade soil).

3. Unroll TENAX MULTIMAT downward and fill the anchorage trenches with topsoil; for base trenches, in case of channels, it is possible to use concrete or stones.

4. Cut the geomat at desired length before anchoring in the lower trench (use scissors or cutter). Overlapping between adjacent rolls shall be about 100 mm, while fixing between adjacent rolls should occur every 1.50 m; overlapping has to be done taking into account (if any) the water flow direction. Rolls may be butt jointed on shallow slope.

5. Fix with "U" shaped pins (F = 8 mm) at every 1.50 m, to ensure a good contact between soil and geomat. Place these pins in the middle of the transversal roll direction and mid-height between lateral pins.

6. Cover completely the geomat with topsoil: fill or brush into the TENAX MULTIMAT, approximately 20 mm of topsoil; spread the recommended grass seeds at a rate of approximately 50gm per sqm.
Alternatively we recommend mixing the topsoil with the seeds prior to filling the TENAX MULTIMAT. On steep slopes perhaps the best method for carrying out seeding over TENAX MULTIMAT is by hydro-seeding the filled geomat. Seeding or hydro-seeding techniques have to be chosen taking into account the climate, sun exposure, the desired cover grade, the environmental aspects of the project, the required time for grass growth.

TYPICAL SLOPE SOIL STABILIZATION



TENAX MULTIMAT 100 should be installed vertically downslope


NOTES:
1. Slope surface shall be free of rocks, clods, sticks and grass. TENAX MULTIMAT 100 shall have good soil contact.

2. Apply permanent seeding or perform hydro-seeding after TENAX MULTIMAT 100 has been installed.

3. Lay TENAX MULTIMAT 100 loosely and stake or staple it to maintain direct contact with the soil. Do not stretch.

4. Cover completely the geomat with topsoil.

  Typical slope soil stabilization with TENAX MULTIMAT geomats
Isometric view - Not to scale
 
products
TENAX MULTIMAT
TENAX International B.V. • Geosynthetics Division
Via Ferruccio Pelli, 14 CH-6900 Lugano, Switzerland • Tel +41+91.9242485 • Fax +41+91.9242489

geo@tenax.net

TENAX SpA - Geosynthetics Technical Office (GTO)
Viale Monza, 1- 20125 Milano (MI), Italy • Tel. +39 02.26113532 • Fax +39 02.28971107

gto@tenax.net

TENAX SpA • Divisione Geosintetici
Via dell'Industria, 3 • I-23897 Viganò (LC), Italia • Tel +39 039.9219307 • Fax +39 039.9219200

geo@tenax.net

© TENAX Group all rights reserved